AS3 Standard Specifications |
MODEL RANGE |
1/2 to 100 HP Heavy
Duty |
1 to 125 HP Normal
Duty |
0.5 to 450 HP Heavy
Duty |
1 to 500 HP Normal
Duty |
Voltage
Rating |
Three-Phase 230 VAC |
Three-Phase 230 VAC |
Three-Phase 460 VAC |
Three-Phase 460 VAC |
POWER REQUIREMENTS |
Input
Tolerance |
Voltage: +10%, -15%;
Frequency: ±5% |
Output
Frequency |
0.01 to 590 Hz |
CONTROL
SPECIFICATIONS |
Control
Method |
Sinusodial Pulse Width
Modulation (PWM); Flux-Field Current Vector Control; Set Point Control (PID) |
Voltage
Regulation |
Main Circuit Voltage
Feedback Control: Automatic, Fixed, & Off |
V/Hz Control |
V/f Constant, Variable
Torque, Automatic Torque Boost, Vector Control, PM Motor Control, 5-point V/F
Custom Setting, & Auto-Tuning |
PWM Carrier
Frequency |
Adjustable 1 to 16 kHz (For
Drive Specific Information Consult Factory) |
Frequency
Setting |
Capacitive Wheel Integrated
into EOI, 0 to 10 VDC, ±10VDC, 4 to 20 mA, Digital Input, Binary Input, &
Motorized Potentiometer Input |
Frequency
Precision |
Analog Input ±0.5% of
Maximum Output Frequency; Discrete/Communications Input ±0.01% of Maximum
Output Frequency |
Speed
Regulation |
Closed Loop (Up to 0.01%,
1000:1 Speed Range), Open Loop (Up to 0.1%, 60:1 Speed Range) |
Main
Protective Functions |
Stall Prevention, Current
Limit, Over-Current, Output Short Circuit, Over-Voltage, Over-Voltage Limit,
Undervoltage, Ground Fault Detection, Input Phase Failure, Output Phase
Failure, Overload Protection by Electronic Thermal Function, Armature
Over-Current at Start-Up, Load Side Over-Current at Start-Up, Over-Torque,
Undercurrent, Overheating, Cumulative Operation Time, Life Alarm, Emergency
Stop, & Various Pre-alarms |
Retry |
User-Set Number of Retries
for Automatic System Restart After Trip |
Restart |
Able to Smoothly Catch
Freewheeling Motor (Bidirectional) |
Overload
Current Rating |
150% for 1 Minute (Heavy
Duty); 120% for 1 Minute (Normal Duty) |
CONTROL INTERFACE |
Digital Input |
8 Discrete Input Terminals
Programmable to 101 Functions (May Be Increased Using Optional Hardware) |
Digital
Output |
3 Discrete Output Terminals
Programmable to 127 Functions; 2 Form-A Contacts & 1 Form-C Contact |
Analog Input |
3 Programmable: One 4 to 20
mA Input, One 0 to 10 VDC Input, & One ±10 VDC Input |
Analog Output |
2 Programmable: 4 to 20 mA
or 0 to 10 VDC |
Communication
Ports |
2 Ports Ethernet IP; 2
RS485 Ports (TSB or MODBUS RTU Protocol) |
ELECTRONIC OPERATOR
INTERFACE (EOI) |
Display |
Full English LCD Display
for Programming, Monitoring & Diagnostics, Red Lit for Faults and Trips |
LED
Indicators |
DC Bus Charge Indicator,
Hand/Auto, Run/Stop |
Keys |
F1 to F4 Multifunction
Keys, Esc, Hand/Auto, Run, Fwd/Rev, [i] Information Key, Stop/Reset & OK;
Capacitive Touch Wheel for Parameter Navigation, Settings, & Control |
Monitoring |
Frequency Command Screen;
Multiple Parameters Displayed: Output Frequency, Forward/Reverse Run, Output
Current, Input Voltage (DC Detection), Output Voltage, Torque, Inverter Load
Factor, Motor Load Factor, Braking Resistor Load Factor, Input Power, Output
Power, Input Terminal status, Output Terminal Status, Overload/Regional
Setting, PID Feedback Value, Stator Frequency, Parts Replacement Alarm,
Cumulative Operation Time, & Past Trips |
CONSTRUCTION |
Enclosure |
RAL 7016/7035 Gray; IP20 (up to 100 HP HD 460V, 125 HP ND 460V, 50 HP
HD 230V, 60 HP ND 230V); Wall-Mount; Front-Access Only |
Power Cables |
Bottom Access for
Input/Motor Cables |
Cooling |
Self-Cooling/ Forced
Air-Cooled |
Standards
& Compliances |
UL Listed in US &
Canada, CSA, & CE |
AMBIENT CONDITIONS |
Ambient
Temperature |
-15 to +60 C (Note: See
Manual for Details, Ambient Temperatures Above 40°C May Require a De-Rate) |
Altitude |
3300 ft. Above Sea Level
(Up to 16,000 ft. with Derate) |
Humidity |
95% Maximum
(Non-Condensing) |
Installation |
Indoors; No Direct
Sunlight; Protects from Corrosive Gas/Explosive Gas/Flammable Gas/Oil
Mist/Dust; Vibration of Less Than 5.9 m/s2 (10 to 55 Hz) |